TESTS AND ADJUSTMENTS (CONTINUED)
STARTING ENGINE
CAUTION
Shroud door panel must be in place when
operating engine. Engine damage could result
from as little as 1 minute full-load operation
without door in place.
NOTE
Provide supply of clean fuel (item Appx C). Make
sure engine
proper oil (LO 9-2380-267-12 or
LO 9-2350-256-12).
If engine is cold and ambient temperature is above 55
A
switch PREHEAT to MOM ON for 20 seconds (1 minute if
than 55 `F) and hold in ON position.
B
Place FUEL SHUTOFF switch in ON position.
CAUTION
Stop engine immediately if speed exceeds 2000
100 rpm. Adjust governor setting.
c
Hold START switch in ON position.
D
Release START and PREHEAT switches after engine starts.
E
Check engine rpm immediately. Adjust governor for correct
ENGINE MOUNTED ON TEST STAND
rpm if necessary (p 4-16).