ROCKER ARM COVER ASSEMBLY REPAIR (CONTINUED)
CLEANING
WARNING
Dry-cleaning solvent used to clean parts is poten-
tially dangerous to personnel and property. Do
not use near open flame or excessive heat. Flash
point of solvent is
A
Clean gasket mating surfaces with dry-cleaning solvent
(item 8, Appx
or mineral spirits paint thinner (item 21,
Make sure mating surface is free of excess gasket material.
B
c
Wipe dry with lint-free cloth (item 6, Appx C).
Clean four drain holes with fine cleaning wire.
D
E
Flush oil line with clean diesel fuel.
WARNING
Particles blown by compressed air can be
dangerous. Direct air stream away from person-
nel in immediate area.
F
Dry oil inlet with clean, filtered,
compressed air.
INSPECTION AND REPAIR
C Inspect bolt holes for damaged or excessively worn threads.
A Inspect cover for cracks, nicks or dents in gasket mating
D Replace rocker arm cover assembly if damaged.
surface.
E
Inspect oil line for cracks, punctures, nicks and dents that
B Inspect area around lifting bracket bolt hole for cracks.
may leak or limit oil flow. Replace if defective.
0859
TM
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |