AIR CLEANER INTAKE ADAPTER AND MANIFOLD HEATER REPAIR (CONTINUED)
INSTALLATION
A
Install new gasket
B
Install intake adapter (2) over studs (3) and gasket
c
Install two nuts (4).
D
Tighten nuts (4) to 13-15
CAUTION
Failure to correctly install glow plug lead
assembly could damage electrical system
and manifold heaters.
Install two glow plug leads (5) on heater (6).
E
F
Install preheat solenoid lead
on heater (6).
Install and tighten heater nut (8).