Remove
1. Remove impeller drive shaft (A) from pressure
housing.
2. Cut locking wire and remove four slotted nuts (B) and
flat washers attaching scavenge oil pump inlet scoop on
housing.
3. Remove inlet scoop (C) from housing.
4. Remove scavenge oil pump inlet screen (D) from
housing.
Install
1. Position scavenge oil pump inlet screen (D) in
housing.
2. Position scavenge oil pump inlet scoop (C) on
housing.
3. Install four slotted nuts(B) and flat washers securing
1. Mount impeller drive shaft with assembled cluster
inlet scoop on housing and install locking wire securing
gear (A) in arbor press.
nuts.
2. Press drive shaft(B) from ball bearing in gear.
4. Install impeller drive shaft (A) in pressure housing.
Figure 6-84. Pressing impeller drive shaft
Figure 6-83. Removing or installing scavenge
from ball bearings in drive cluster gear.
oil pump oil inlet scoop (FSN 2815-895-6430
oil pump).
6-83
|