Remove
Install
1. Remove self-locking nut (A) attaching loop clamp to
1. Install two loop clamps on fire extinguisher tube (C)
front fan drive housing.
and position tube in engine.
2. Remove self-locking nut (B) attaching loop clamp to
2. Position clamps as shown and install self-locking nut
rear fan drive housing,
(B) securing one clamp to rear fan drive housing.
3. Remove fire extinguisher tube (C) and clamps,
3. Install self-locking nut (A) Becuring second clamp to
Remove two clamps from tube.
front fan drive housing.
4. Remove two cap screws (D) and lock washers and
4. Remove two cap screws (D) and lock washers from
remove breather tube support bracket from fuel in-
fuel injection pump. Install breather tube support
jection pump. Reinstall cap screws and lock washers in
bracket on pump and secure with two cap screws and
pump.
lock washers.
Figure 5-89. Removing or installing fire extinguisher tube-engines
prior to new tube and clamps.