TM 9-2520-270-34
INSTALL
32. IF PUMP HOUSINGS WERE
SEPARATED FOR INSPECTION,
GO TO STEP 34.
33. IF PUMP IS BEING REPLACED,
GO TO STEP 40.
34. JOIN HOUSING (1) TO HOUSING (2).
a. Coat shafts (3) and bushings (4)
with transmission oil.
b. Aline dowel pins (5) in top
housing (2) with pilot holes in
bottom housing (1).
c. Join housings (1) and (2).
d. Check shafts (3) for free rotation.
e. If shafts (3) do not rotate freely,
go to step 27.
35. INSTALL EIGHT SHORT SCREWS (6)
AND FIVE LONG SCREWS (7).
a. Install eight washers (8) and
short screws (6).
b. Install five washers (9) and long
screws (7).
36. USING 3/8-lNCH DRIVE TORQUE
WRENCH AND 7/16-lNCH SOCKET,
EVENLY TORQUE EIGHT SCREWS (6)
TO 100-120 in-lb (115-138 cmkg).
37. USING 1/4-lNCH DRIVE TORQUE
WRENCH, EXTENSION AND 7/16-lNCH
SOCKET, EVENLY TORQUE FIVE
SCREWS (7) TO 100-120 in-lb
(115-138 cmkg).
4-490
|