TM 9-2520-270-34
28. ROTATE PUMP SHAFTS (1).
29. INSPECT INNER SURFACES (3) OF
BOTTOM HOUSING (4) FOR GOUGING.
a. If shafts (1) and inner pump
elements (2) rotate, go to step 29.
a. If inner surfaces (3) are not damaged,
go to step 30.
b. If either shaft (1) or inner pump
b. If either inner surface (3) is
element (2) does not rotate, go to
damaged, go to step 39.1
step 39.1.
NOTE
Pump elements are a matched set. Do not
remove pump shafts or elements.
31. INSPECT TOP HOUSING
30. INSPECT BOTTOM HOUSING
INSERTS (6). See page 2-5.
INSERTS (5). See page 2-5.
a. If inserts (6) are not damaged,
a. If inserts (5) are not damaged, go to
go to step 32.
step 31.
b. If any insert (6) is damaged,
b. If any insert (5) is damaged, go to
go to step 39.1
step 39.1.
GO TO NEXT PAGE
4-489
Change 2
|