TM 9-2520-270-34
8.
IF OUTER ROTOR (2) AND
RING (1) HAVE COME APART, GO TO
STEP 9. IF NOT, GO TO STEP 10.
ASSEMBLE OUTER ROTOR (2)
9.
CAUTION
AND RING (1)
Keep eccentric ring and outer rotor together
when removing from housing. Spring and vane
a. Install spring (4) and vane (5) into
can be lost and equipment can be damaged.
rotor (2).
7. PULL OUT RING (1) AND OUTER
b. While holding spring (4) and vane (5)
ROTOR (2) FROM LIQUID PUMP
with thumb, insert rotor (2) into
HOUSING (3) AS ONE UNIT.
ring (1).
11. CHECK INSIDE DIAMETER OF
10. CHECK INSIDE DIAMETER OF PUMP
SLEEVE BEARING (7).
HOUSING CAVITY (6).
a. Using telescoping gage set and
a.
Using telescoping gage set and
micrometer caliper set, measure
micrometer caliper set, measure
inside diameter of bearing (7).
diameter of cavity (6).
If measurement is greater than
b.
b.
If measurement is greater than
3.8775 inches (98.489 mm), go to
1.002 inches (25.45 mm), go to
step 12.1, If not, go to step 11.
step 12.1. If not, go to step 12.