Page Title: REMOVE PUMP PLATE ASSEMBLY
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2520-270-34
CAUTION
Eccentric ring, outer rotor, spring, and vane
may fall out when removing plate assembly.
Equipment damage can result.
Inner and outer rotors must stay a matched
set. Damage to equipment can occur.
4. REMOVE PUMP PLATE ASSEMBLY (1).
a. Turn liquid pump housing (2) over.
b. Carefully break loose oil suction
between plate assembly (1) and
housing (2).
Hold eccentric ring (3) and outer
c.
rotor (4) in place while removing
plate assembly (1).
5. CHECK PLATE ASSEMBLY (1).
a. Using telescoping gage set and
micrometer caliper set, measure
inside diameter of sleeve bushing (5).
b. If diameter of sleeve bushing (5) is
greater than 1.002 inches (25.45 mm),
go to step 5.1. If not, go to step 6.
REPLACE PLATE ASSEMBLY (1).
5.1
RECORD FAILURE ON DA FORM 2407
6. REMOVE SHOULDERED SHAFT (6)
AND RETURN DEFECTIVE PLATE
AND INNER ROTOR (7).
ASSEMBLY TO DEPOT.
GO TO NEXT PAGE