TM 9-2520-270-34
9. CHECK GEAR (1)
a. Using mechanical puller kit, remove
and discard two bearings (2).
b. Using retaining-ring pliers (Item 61),
remove retaining ring (3).
c. Using telescoping gage set and
micrometer caliper set, measure
bearing bore (4).
d. Replace gear (1) if measurement is
greater than 3.1495 inches
(79.997mm).
10. CLEAN POWER TAKEOFF ASSEMBLY.
a. Clean assembly and hardware. See
11. INSPECT POWER TAKEOFF ASSEMBLY.
a. Inspect assembly, piece parts, and
inserts. See page 2-5.
b. Repair inserts if damaged. See task
REPAIR POWER TAKEOFF HOUSING
INSERTS, page 4-148.
12. IF BEARINGS (2) WERE REMOVED, GO
TO STEP 13. IF NOT, GO TO STEP 15.
13. USING RETAINING-RING PLIERS
(ITEM 61), INSTALL RETAINING
RING (3) IN GEAR (1).
14. PRESS BEARINGS (2) INTO GEAR (1)
a. Using arbor press, install bearings (2)
in gear (1) so that bearings are seated
against retaining ring (3),
4-146