CAUTION
Use care when lifting controller to prevent
damage. Keep hands free of internal controller
parts. Do not set controller on workbench top
side up. Use care when setting controller
down to prevent damage to controller parts.
11. REPAIRER AND HELPER REMOVE
CONTROLLER ASSEMBLY (5).
CAUTION
Pry up controller assembly (5) under
a.
Openings in controller assembly must be
two plugs (6).
covered with clean rags to prevent parts
from falling into transmission. Damage to
b.
Repairer and helper lift controller
equipment can occur.
assembly (5) straight up and remove
from transmission (9). Place on
10. REMOVE 24 SCREWS (1).
workbench bottom side up.
a.
Cover holes (2) and (3) with clean
Remove and discard gasket (7).
c.
rags.
Remove 24 screws (1) and lock
b.
12. USING CLEAN WIPING RAG, COVER
washers (4). Discard lock washers
CONTROLLER OPENING (8) ON
c.
Remove rags.
TRANSMISSION (9).
13. INSPECT HELlCAL SPRINGS (10), (11)
FOR DAMAGE.
a. If no spring (10), (11) is bent or
broken, go to step 14. If any spring is
bent or broken, go to step 15.