TM 9-2520-270-34
REMOVE CAP (3).
a. Using hammer and punch, rotate cap (3)
to the right. Rotate until pry bar can
I
be placed under a corner (4) of cap.
2. REMOVE FOUR SCREWS (1) AND
b. Using pry bar under cap (3), pry up
LOCK WASHERS (2). DISCARD
cap and lift off.
LOCK WASHERS.
6. CHECK ELEMENT (5) FOR METAL CHIPS.
a.
If chips are found, check main
transmission filter for chips. See task
INSPECT TRANSMISSION FOR
CONTAMINATION, page 4-67.
If no chips are found, go to step 7.
b.
NOTE
Filter element may be found either on cap or in
WARNING
hole.
Solvent fumes can burn and
could poison you. Read warn-
4. REMOVE FLUID FILTER ELEMENT (5).
ing in the front of this
a. Pull element (5) from cap (3) or
manual.
hole (6).
b. Cover hole (6) with clean rag.
7. CLEAN ELEMENT (5).
5. REMOVE AND DISCARD TWO
a. Using cleaning solvent, clean
PREFORMED PACKINGS (7) AND
element (5).
HYDRAULIC O-RING (8).
3-6
|