2-19. Hydraulic System--Reverse-Range
manual selector is at the 2-3 position, the trans-
Operation
mission cannot downshift to low range. This is
prevented by a main pressure branch, at the top,
a. Main-Pressure Circuit (red--fig. 2-8).
left side of the manual selector valve bore, which
(1) In reverse-range operation, the main
directs main pressure to the upper area surface of
pressure circuit functions as described in paragraph
the low-intermediate shift plug, and to the lower
2-15a, except for the distribution of oil at the
end of the shift valve. This pressure holds the low-
manual selector valve. Here, the valve is at its
intermediate shift valve upward as long as the
extreme upward position. This permits oil to flow
manual selector is at 2-3 position.
into the reverse-range clutch circuit. When the
valve is at any other position, the reverse-range
2-7). In high-range (2-3) operation, the other
clutch exhausts into the manual selector valve bore
circuits operate as described in paragraph 2-17 for
above the selector valve.
high-range (1-2-3) operation.
|