TM 746-10
apparatus, hand tools, and other accessories. Drain the
Dry the compressor using procedure D-1 or D-4, as
pump and flush with P-10, grade 30. Preserve truck
applicable. Clean nonmetallic items by wiping with a
chassis and pump unit engine, as described in
clean, dry cloth.
(3) Unit pack.
(2) Preservative application. Drain engine
crankcase and compressor pump, fuel tank, fuel system,
(a) Truck-mounted
decontaminating
air cleaner, and water separator. Remove the air
apparatus. Wrap preserved areas, hand tools, and
cleaner and coat interior with P-10, grade 30. Reinstall
other accessories with greaseproof, waterproof barrier
the air cleaner. Remove spark plug and fog one-half
material and secure with tape. Place hand tools and
ounce of P-10 into the combustion chamber. Reinstall
other accessories in their respective compartments.
the spark plug. Fog the interior of the fuel tank using
Cover glass surfaces with tape. Seal all openings to the
the same preservative oil. Seal all openings (air
pump interior, fire extinguisher nozzles, fitting, hoses,
cleaner, oil dipstick, exhaust, etc.) to the interior of the
seams of storage chest, edges of hopper, pump
engine using tape.
compartment, and hood with tape.
Secure the
discharge hoses in place on the reels with the same
(3) Packing. Pack each compressor in a box
tape. Coil the 30-foot length of hose and secure the coil
fabricated from wood or plywood. Block and brace the
in three places with filament-reinforced tape. Place the
compressor to restrict movement within the box by using
coil on the left-hand rail and secure it with straps
wood or fiberboard pads. Close the box and apply 3/4-
provided. Secure the power take-off lever in the
inch galvanized steel strapping.
disengaged position with filament-reinforced tape.
(b) Skid-mounted
decontaminating
b. Unserviceable,
economically
reparable
apparatus. Cover the louvers on the water heater with
retrograde materiel. Clean, dry, preserve, pack, and
watervaporproof barrier material and secure with tape.
mark the same as for serviceable retrograde materiel,
Cover the heater control panel with weather-resistant
as specified in a above, except include condition code
fiberboard or Y4-inch plywood and secure in place with
"F" in the marking.
tape. Completely drain tank assembly, components of
c. Serviceable materiel to be recycled. Clean, dry,
personnel shower assembly, and suction and blender
preserve, and pack per a above. Mark per paragraph 3-
hoses. Insert blender hose into suction hose. Cover
5.
ends of the suction hose with greaseproof, waterproof
barrier material and secure with tape. Coil the hoses on
4-149. Decontaminating Apparatus, Power-driven
top of the tank assembly and secure with clamps
provided. Seal ends of the exhaust extensions with
a. General.
This paragraph pertains to the
tape. Coil the exhaust extensions and place inside the
following decontaminating units:
coiled suction hose and secure to the suction hose with
(1) Truck mounted, M9.
filament-reinforced tape. Seal all openings to the tank
assembly with tape. Close tank drain valve and back off
(2) Skid mounted, 500 gallon, M12A1.
two turns. Place personnel shower piping in weather-
b. Serviceable retrograde materiel.
resistant fiberboard boxes and close with tape. Secure
(1) Cleaning and drying.
Clean all
the pump unit battery in battery carrier with tape.
component items of the decon apparatus using process
C-1.
Clean exterior of the truck-mounted and
(4) Packing. Do not apply additional packing.
skidmounted decon apparatus with water under pressure
or steam.
Dry using procedure D-1 or D-4, as
applicable. Clean nonmetallic items by wiping with a
c. Unserviceable,
economically
reparable
clean, dry cloth. Clean interior of tank, tank agitator
retrograde materiel. Clean, dry, preserve, and pack per
pipe, and blender pipe by flushing with water.
b above. Mark per paragraph 3-5.
CAUTION
4-150. Mask, Chemical-biological and Gas
Do not direct water under pressure,
a. General.
This paragraph pertains to the
steam, or compressed air into
following masks:
precision equipment or instruments.
(1) Chemical-biological, M9, M9A1, M14A2,
M16, M17, M17A1, M18, M22, M24, M25, and M25A1.
Drain the system and repeat, as necessary, to ensure a
(2) Mask, gas, M10, M11A1, M12, M21, and
clean system.
M26A1.
(2) Preservative application. Apply P-2 to all
(3) Mask, riot control agent, M23.
bare, metal machined surfaces of each decontaminating
4-80
|