4920-01-139-4534">
|
|
TM 55-4920-439-13&P
SECTION II. EQUIPMENT DESCRIPTION AND DATA
1-6. Characteristics.
a.
The Electric/Instrument Shop is housed in a tactical, one side expandable, shelter (NSN 5411-01-124-1377).
b. Once the shelter has been erected the additional floor space provides the work area necessary for the
Electric/Instrument Shop to perform its maintenance function.
c. The shop is equipped with tools, machines and equipment necessary to provide instrument and electrical repair
for the AVIM unit.
d. The shelter can be transported by highway, rail, marine or air (C-130, C-141 or C-5 aircraft, Army CH-47 and CH-
54 helicopter).
e. As designed, the Electric/Instrument Shop can be operated in any geographic area and under any climatic
condition in support of Army non-divisional units.
1-7. Location and description of major components.
a.
Shelter closed for transport or storage.
b.
Equipment, location in transport/storage mode.
(1)
ECU
(2)
CABINET, BIN STORAGE
(3)
VISE
(4)
EXHAUST GAS TESTER
(5)
SMALL CABINET, W/DRAWERS
(6)
CABINET, BIN STORAGE (STACKED)
(7)
GRINDER
(8)
CABINET, W/DRAWERS
(9)
DRILL PRESS
(10)
D.C. POWER SUPPLY
(11)
TOOL BOX RACK
NOTE
ITEM (4) MAY NOT BE ISSUED WITH
THIS SHOP SET, BUT IF REQUIRED,
CAN BE OBTAINED BY SEPARATE
REQUISITION.
1-2
|