4920-00-176-9236 ">
|
|
TM 55-4920-424-13&P
SECTION VI
TROUBLESHOOTING
6-1.
GENERAL
6-2.
System troubles listed in figure E-18 may be the result of the probable cause indicated, Many of the troubles listed
are based on practical experience; however, the causes listed are not the only faults that can cause the specified trouble,
Unique situations will require special approaches. Repair instructions recommended in the REMEDY column are
referenced in the applicable paragraph in Section VII. Figure E-18 lists troubleshooting data in the following manner:
a. Trouble. Various troubles that may be encountered during check stand operation.
b. Probable Cause. The probable cause of a particular trouble are listed in the order in which they are most likely to
occur under standard operating conditions.
c. Remedy. Remedies are similarly arranged, but in order of complexity, starting with the simplest remedy. Refer to
the wiring diagram and electrical schematic enclosed in back of this manual when performing electrical checks.
Trouble
Probable Cause
Remedy
1.
Fuel not
a.
Fuel supply low.
Check fuel level, and add
reaching
fuel if necessary.
APU
b.
Loose connections,
Tighten loose connections.
crimps, or restrictions
Clear restrictions, and
in fuel lines.
replace all damaged lines
c.
Restricted fuel
Remove restrictions.
intake tube, or
tank breather
vent dogged.
d.
Defective fuel
Check fuel boost pump for
boost pump.
proper operation.
e.
Fuel filter
Replace filter element.
clogged.
Refer to paragraph 7-8,
for replacement procedure.
f.
Entrapped air
Purge the fuel system.
in the fuel System.
Refer to paragraph
purging procedure is
applicable.
(Figure E-18 Sheet 1 of 2)
(Figure E-18 Sheet 2 of 2)
Figure E-18. Table of Troubleshooting Procedures (Sheet 1 of 2)
Change 2 E-51
|