TM 55-4920-424-13&P
Trouble
Probable Cause
Remedy
8.
Control
Malfunctions of the APU are not
Console.
fully discussed in this manual.
When APU troubles occur, follow
the troubleshooting instructions
outlined in TM 55-2835-203-24 to
isolate the cause. Troubles traced
to the control console must be
located by a continuity check to find
the defective component. Refer to
control system malfunction infor-
mation. Refer to drawings in
enclosure for continuity checks.
Figure 6-1. Table of Troubleshooting Procedures (Sheet 5 of 5)
6-3. TROUBLESHOOTING ELECTRICAL CONTROLS.
6-4. Malfunctions in the APU controls should be traced only after it has been established that the battery is in good
condition and that all electrical connections are correctly and tightly connected. It is recommended that APU electrical
components be checked for proper operation before troubleshooting the check stand control components.
6-5. Before performing any troubleshooting procedures, always verify that the power supply components to the APU
controls are functioning properly, furnishing 24-volt dc power to the control circuits, and are charging the battery. The
following components comprise the power supply to the APU.
Battery
B contacts of relay K2
Circuit breaker CB1
Indicator light DS6
Circuit breaker CB2
DC starter-generator G#
Reverse current cutout K6
DC voltage regulator VR1
Starter dropout relay K7
Resistor R3
6-6. If fuel supply problems are encountered, first check switch S1, and then check the boost pump for proper operation.
6-7. If the fuel control system does not operate correctly, carefully check the function of each APU control component and
the corresponding relay contacts in the console.
6-5
|