TM 55-4920-416-13
Section IV
NAVAER 17-15C-539
(ac or dc) is applied to this receptacle as required. In
4-22. ALTIMETER AND RATE OF CLIMB (5, figure 4-3). This
conjunction with the power cables, its internal wiring
connection is used for testing altimeters and rate-of-climb
automatically adjusts the circuit of the test set to operate from
indicators; for connection to the static side of airspeed
the power supplies specified in Section I, Table 1-2.
indicators when checking at altitudes other than sea level, and
for checking Mach meters.
It is usually convenient to
4-19. FUEL PRESSURE (2, figure 4-3). This connection is
simultaneously test the altimeter, rate-of-climb meter, and
used only when testing fuel pressure gauges rated up to 25
airspeed indicator by connecting up two hoses to the last two
psig.
connectors (4 and 5).
4-20. MANIFOLD PRESSURE (3, figure 4-3). This connection
4-23. OPERATION PROCEDURES.
is used when testing manifold pressure gauges covering the
range from 10 to 75 inches of Hg absolute.
4-24. PRE-OPERATION. Special hydraulic oils are required
for the proper operation of VPT-7A, depending upon
4-21. AIRSPEED (4, figure 4-3). This connection is used
environmental conditions.
For details see Section II,
when testing and calibrating airspeed indicators calibrated in
knots or miles per hour. When checking Mach meters this
weather, warm the set by operating the pump for not less than
connection must be used in conjunction with the altimeter
5 minutes, with both selector valves set at OFF and the
connection.
VACUUM and PRESSURE controls 1, 2, 3 and 4 fully
Figure 4-4. Pitot System Test