TM 55-4920-325-14&P
S e c t i o n Ill. MEASURING TANK UNIT PROBE
INSULATION RESISTANCE
tive cover from Megohmmeter MIDSCALE ADJ
2-7. Scope.
control (16). Using insulted screwdriver, adjust
This section contains information and in-
Megohmmeter MIDSCALE ADJ control (16) until
structions for measuring tank unit probe in-
MEGOHMMETER indicator (14) pointer is on
sulation resistance on aircraft using liquid fuel
MIDSCALE calibration mark. Do not replace Me-
gaging systems.
gohmmeter MIDSCALE ADJ control (16) cover at
this time.
2-8. Operating Procedure.
WARNING
(5) Repeat steps (1) through (4), above,
as often as necessary until proper indications are
Do not operate ungrounded test set.
obtained.
Proceed as follows to measure tank unit probe in-
( 6 ) Install Megohmmeter ZERO ADJ
sulation resistance.
control (15) cover and Megohmmeter MIDSCALE
ADJ control (16) cover.
a. Check that the grounding lead has been
properly connected (see 2-4 b).
g. To measure leakage resistance between
elements of tank unit main probe, set FUNCTION
b. Check that power cable is connected from
SELECTOR switch (25) to TANK UNIT TEST-
test set to 115 volts, 400 Hz, single phase power
UNSH. To measure leakage resistance between
source (see 2-4c through e).
elements of tank unit compensator, set FUNC-
c. Connect test set to aircraft liquid quantity
TION SELECTOR switch (25) to TANK UNIT
fuel gage system as shown in figure 2-3.
TEST-COMP.
d. Set Power ON/OFF switch (2, figure 2-1)
NOTE
to ON and allow test set to warm up for at least
The three center positions of CAP-RES
five minutes.
CHECK switch (13) have letter designa-
e. Set CAP-RES CHECK switch (13) to EXT
tions A, B, and C which correspond to
RES position.
TANK UNIT connectors (10), (11), and
f. Check that MEGOHMMETER indicator
(12); A designates the coaxial con-
(14) is properly calibrated at ZERO and MID-
ductor, B designates the unshielded
conductor, and C designates the com-
SCALE points of indicator as follows:
pensator conductor.
( 1 ) Set Megohmmeter RANGE SE-
h. Set CAP-RES CHECK switch (13) to posi-
LECTOR switch (17) to ZERO CAL.
tion corresponding to resistance measurement to
(2) Observe that MEGOHMMETER indi-
be made.
cator (14) pointer is deflected to ZERO calibration
i. Set Megohmmeter RANGE SELECTOR
mark on dial. if pointer does not deflect to ZERO
switch (17) to multiplier setting so that ME-
calibration mark, unscrew protective cover from
GOHMMETER indicator (14) displays a reading
Megohmmeter ZERO ADJ control (15). Using in-
closest to midscale. For example, if resistance to
sulated screwdriver, adjust Megohmmeter ZERO
be measured is 50 megohms, the resistance can
ADJ control (15) until MEGOHMMETER indicator
be measured when Megohmmeter RANGE SE-
(14) pointer is on ZERO calibration mark, Do not
LECTOR switch (17) is set to X10, X100, or X1000
replace Megohmmeter ZERO ADJ control (15)
positions. However, an accurate value can be
cover at this time.
measured only at X100 setting. In the example
given, setting Megohmmeter RANGE SELECTOR
( 3 ) Set Megohmmeter RANGE SE-
switch (17) to X100 position causes indicator to
LECTOR switch (17) to MIDSCALE CAL.
read 0.5. Multiply reading displayed on ME-
(4) Observe that MEGOHMMETER indi-
GOHMMETER indicator (14) by setting on Me-
cator (14) pointer is deflected to MIDSCALE cal-
gohmmeter RANGE SELECTOR switch (17) to de-
ibration mark on dial. If pointer does not deflect
termine actual resistance in ohms.
to MIDSCALE calibration mark, unscrew protec-
2-12
|