Figure 3-55. Injector in Calibrater J22410.
(41) Allow the injector to be operated for 30 seconds to purge any air.
(42) Press the red fuel flow start button to start the flow of fuel into the vial. The fuel flow will stop
after 1000 strokes.
(43) Set all switches (motor and power control) to off.
(44) The amount of fuel in the vial should be between 57 and 62.
(45) If the injector does not meet the above steps, repair the injector.