(4) Lift up on the sub-cap assembly until a definite snap indicates that the fuel rod and collar have been freed
from the terminal lever cross pill. Then, remove the sub-cap assembly, pulling the fuel rod out of the hole
in cylinder head and throttle control rod mounting bracket.
(5) Remove four bolts (6, figure 3-17) and four lockwashers (7) and lift the governor housing (8) away from the
drive housing. Remove governor housing gasket (9).
(6) Remove six drive housing bolts (10) and six flat washers (11) and separate the drive housing (12) from the
blower. Remove drive housing gasket (13).
Figure 3-17. Governor, Removal/Installation
Figure 3-18. Top View of Governor with Cover Removed.
3-41