3-13. ACCUMULATOR-Continued.
f. Reassembly-Continued.
(8) Install nut (4), gasket (3), valve assembly (2), and cap (1). Torque to 45-50 ft-lb (5.08-5.65 N).
(9) Before attaching chuck (1, figure 3-13) to valve assembly on accumulator, be sure valve (2) is in the
closed position. Valve is closed when handle is turned clockwise.
WARNING
Nitrogen is flammable and can burn skin and irritate eyes. Eye and skin protection are required. Use only
in a well-ventilated area, away from open flames.
(10) Connect nut (3) to nitrogen tank and tighten.
(11) Open valve (2) and slowly open valve on nitrogen tank to allow gas to flow into the accumulator, closing
occasionally to allow needle on gauge (4) to settle in position. The accumulator is fully charged when 1500
psi is indicated on gauge (4).
Figure 3-13. Accumulator Charging Set-Up.
g. Installation.
(1) Refer to figure 3-11 and install accumulator (11) with four clamps (10) and four screws (9).
3-32
|