TM 55-1930-208-24
3-12. HYDRAULIC PUMP-Continued.
e. Reassembly-Continued.
(15) Refer to TM 55-1930-208-10, paragraph 3-12 and install the pump.
3-13. ACCUMULATOR.
This task covers:
a. Removal
b. Disassembly
c. Cleaning
d. Inspection
e. Repair
f. Reassembly
g. Installation
INITIAL SET-UP:
Tools Required:
Tool Kit, General Mechanic's (Item 1, Appendix B)
Wrench, Torque (Item 71, Appendix B)
Materials Required:
Cloth, Crocus (Item 5, Appendix C)
Gasket P/N GA100117
Gasket P/N GA100475
Oil, Lubricating (Item 12, Appendix C)
Ring P/N RG100155
Ring P/N RG203187-1
Seal P/N GA1128-9
Seal P/N SE202992-27
Solvent, Cleaning (Item 4, Appendix C)
Washer, Lock P/N MS35338-46
Washer, Lock P/N WA6-16
Equipment Conditions:
Engine shut down (paragraph 2-11, TM 55-1930-208-10).
a. Removal. (Refer to figure 3-11).
(1) Remove cap (1) and loosen locknut (2) on valve assembly until all gas escapes.
(2) Remove hoses (3 and 4). Remove adapter (5), elbow (6), tee (7), and adapter (8).
(3) Remove four screws (9), four clamps (10), and accumulator (11).
(4) Remove four nuts (12), four lockwashers (13), four screws (14), and bracket (15).
3-28
|