TM 55-1915-200-10
B
Table 2-2. Operator/Crew Preventative Maintenance Checks and Services
EQUIPMENT NOT READY/AVAILABLE
- BEFORE D - DURING A - AFTER W - WEEKLY M - MONTHLY Q - QUARTERLY S/A SEMI ANNUALLY AN - ANNUALLY
IF
T/A - TRIENNIALLY
ITEM
B
D
AWM
Q S/A AN T/A
ITEMS TO BE INSPECTED
CHECK FOR
ACTION
PMC
NMC
NUMBER
X
X
Check bromine feeder assembly for secure
Clean/repair as necessary.
mountings, dirt buildup and corrosion.
X
Bypass Header Assembly
Check for leaks from inlet and outlet connections. Repair leaks as necessary.
X
Check for damaged or missing parts.
Repair/replace damaged or
missing parts.
X
X
X
Time Totalizer
Check that time totalizer operates.
Troubleshoot/repair as
necessary.
X
Feeder Light
Check that indicator light operates.
Troubleshoot/repair as
necessary.
X
Cartridge Change
Check that indicator light operates.
Troubleshoot/repair as
necessary.
X
Test Tap
Check for presence of bromine in water.
Add if necessary
Bromine level low.
X
Check solenoid valve for leaks at all connections. Tighten as necessary.
X
Check for damaged or missing parts.
Repair/replace damaged or
missing parts.
X
Feeder Assembly
Check for leaks from inlet and outlet connections. Repair leaks as necessary.
X
Check for damaged or missing parts.
Repair/replace damaged or
missing parts.
X
Check that top gasket is not worn or damaged.
Replace worn or damaged
gasket.
X
Check that safety glasses and dust mask are
Replace damaged or
Do not operate
90
Orbital Drill Press OR-
available and are serviceable.
missing safety equipment. equipment if
2501F
safety
equipment is not
available or
unserviceable.
LSV PMCS
Change 12
2-291
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |