TM 55-1915-200-10
B
Table 2-2. Operator/Crew Preventative Maintenance Checks and Services
EQUIPMENT NOT READY/AVAILABLE
- BEFORE D - DURING A - AFTER W - WEEKLY M - MONTHLY Q - QUARTERLY S/A SEMI ANNUALLY AN - ANNUALLY
IF
T/A - TRIENNIALLY
ITEM
B
D
AWM
Q S/A AN T/A
ITEMS TO BE INSPECTED
CHECK FOR
ACTION
PMC
NMC
NUMBER
X
Salinity light
Check that salinity light is OFF. If the light is ON, Troubleshoot, repair as
Limited
56 cont
all water is being diverted to drain.
necessary.
underway time.
X
Vacuum Pressure
Check vacuum pressure
Troubleshoot, repair as
Pressure
necessary.
exceeds 25" Hg.
X
Check back flush pressure.
Troubleshoot, repair as
Pressure
57
Oily Water Separator
necessary.
exceeds 15 PSI.
58
Orca II 165A (If Equipped)
X
Pumps
Check pumps for unusual noise and/or
Troubleshoot, repair as
malfunction.
necessary.
X
Electric motors
Lubricate ball bearings on the drive and fan side
Repair/replace as
of motor.
necessary.
X
Inspect motors for moisture penetration.
Repair/replace as
necessary.
WARNING
High voltages are present in the control panel.
The main breaker should be open (OFF),
locked and tagged out before opening control
panel.
X
Control Panel
Ensure the interior of the panel is dry and all
Clean the interior and
terminal connections are tight.
tighten connections as
necessary.
X
X
Treatment tank and sediment Inspect for leaks by observing connections,
Tighten all leaking
module
connections.
fittings, and hoses. The system must be
Repair/replace as
running.
necessary.
X
Inspect the interior and exterior of the tank for
Tighten all loose
corrosion and security of all mountings.
mountings, and remove any
corrosion.
LSV PMCS
Change 12
2-275
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |