Table 2-2. Operator/Crew Preventative Maintenance Checks and Services
EQUIPMENT NOT READY/AVAILABLE
- BEFORE D - DURING A - AFTER W - WEEKLY M - MONTHLY Q - QUARTERLY S/A SEMI ANNUALLY AN - ANNUALLY
IF
T/A - TRIENNIALLY
ITEM
B
D
AWM
Q S/A AN T/A
ITEMS TO BE INSPECTED
CHECK FOR
ACTION
PMC
NMC
NUMBER
X
X
Check for rips, oil stains, broken straps, fiber
Replace as needed. Match
Number required not
15
Life Jackets
number of life jackets to
on board
deterioration and hull number of vessel. Check
personnel on board.
that light and whistle attached to jacket operates
and that case is not damaged.
X
X
Check for rips, oil stains, broken straps, fiber
Replace as needed. Match
Number required not
16
Immersion Suits
deterioration and hull number of vessel. Check
number of immersion suits
on board
that light and whistle attached to suit operates and to personnel on board
that zippers function properly.
X
X
Inspect for damage and proper markings. Check  Replace as needed
Number of rings
17
Life Rings
for operational marker lights when turned upright.
required not on board
Verify that hydro date has
X
Inspect for tight mounting, full charge, corroded
18
Semi-portable CO2 Fire
not elapsed. Weigh
nozzle, and closed valves with untampered seals.
Extinguishing System
cylinders and inspect
Direct particular attention to extinguisher line and
cylinders for visual
nozzle in the engine room, checking for damage
damage.
and correct nozzle alignment.
Check that entire system is in good condition and Refill/replace used fire
X
securely mounted. Check extinguisher nozzle to  extinguishers.
ensure that they are free of obstructions, dirt and
corrosion.
X
Inspect extinguishers for discharged cylinders,
Refill/replace used fire
19
Portable CO2 Fire
and correct weight. "HEFT" the cylinder to prevent extinguishers.
Extinguishers
the compacting of agent.
X
Periodic inspections of the fire suppression
20
Halon 1301 Fixed Fire
system should be made to ensure efficient
Suppression System
operation at all times.