TM 55-1915-200-10
B
Table 2-2. Operator/Crew Preventative Maintenance Checks and Services
EQUIPMENT NOT READY/AVAILABLE
- BEFORE D - DURING A - AFTER W - WEEKLY M - MONTHLY Q - QUARTERLY S/A SEMI ANNUALLY AN - ANNUALLY
IF
T/A - TRIENNIALLY
ITEM
B
D
AWM
Q S/A AN T/A
ITEMS TO BE INSPECTED
CHECK FOR
ACTION
PMC
NMC
NUMBER
10
1 kW Xenon Searchlight
X
Lamp
Visually inspect lamp for blackening.
If black, replace lamp.
Refer to unit maintenance
WARNING
On initial startup, DO NOT energize circuit before
first checking to ensure that the protective lamp
cover is removed. Use extreme care when
performing maintenance work, making
adjustments or operating the searchlight, etc.,
because dangerous high voltage (over 50,000)
radio frequency power is used in the lamp starting
circuit. Observe all warnings to prevent injury or
possible death of personnel.
WARNING
Do not stand close to searchlight front cover when
lamp is lighted. In the event of lamp explosion, the
front cover glass could break. Avoid direct
exposure from the powerful direct and reflected
radiation given off by the lamp. Observe all
CAUTIONS and WARNINGS.
X
Visually inspect for stresses in the quartz.
If stress is detected,
replace lamp.
X
Reflector
Visually inspect for tarnishing, dirt buildup and
Clean as required.
corrosion.
X
Front Cover Glass
Visually inspect glass for dirt buildup and defects. Clean as required.
X
Searchlight
Visually inspect the case for damage, dirt buildup Clean/repair/replace as
and corrosion.
required.
11
Searchlight Power Supply
LSV PMCS
Change 12
2-257
|