TM 55-1905-223-24-7
2-30. Replace/Repair Cleaning Valve Assembly. (FIGURE 2-31)
This task covers: a. Removal,
b. Repair,
c. Replacement.
INITIAL SETUP
Tools
Equipment Condition
Tool kit, general mechanic's,
Watermaker assembly shut down.
Refer to TM 55-1905-223-10.
Watermaker tagged "Out of
Service - Do Not Operate."
Materials/Parts
Nonmetallic hose P/N PVTBF075
Nonmetallic hose P/N PVTBF038
Ball valve P/N TW1005OT
Hose plug P/N TP-4008 (1 each)
Hose plug P/N 3TP-4012 (2 each)
Warning tag, Item 11, Appendix C
REMOVAL
a. Close appropriate inlet feedwater gate valve (2, FIGURE 2-31, Sheet 1).
b. Disconnect external hoses (Sheet 2) from product water port, brine discharge port, and feedwater port. Cover
ports for protection with hose plugs (12, 13, and (14).
c.
Remove four hose clamps (2).
d. Remove four nonmetallic hoses (1).
e. Remove four machine screws (5), flat washers (6), lockwashers (7), and plain hexagon nuts (8) from cleaning
valve assembly.
f.
Remove cleaning valve assembly.
REPAIR
a. Check nonmetallic hoses (1) for cracks and swelling. Discard if cracked or swollen.
b. Check ball valve (4) for corrosion.
2-103
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |