2-20. Replace Axial Pistons Pump.
This task covers: a. Removal, b. Replacement.
INITIAL SETUP
Tools
Equipment Condition
Tool kit, general mechanic's,
RO desalinator shut down.
Refer to TM 55-1905-223-10.
Standard puller, P/N ST 647 RO desalinator tagged "Out of
Service, Do Not Operate."
Materials/Parts
Motor oil, Item 2, Appendix C
Axial pistons pump P/N D1OSS6
Funnel, Item 3, Appendix C
REMOVAL
a. Close appropriate inlet feedwater gate valve (2, FIGURE 2-14, Sheet 1) for unit.
b. On left side of RO desalinator unit, remove ten machine screws (2, FIGURE 2-14, Sheet 2) and remove louvered
panel (1) from unit.
c.
On main frame assembly (3) remove element machine screws (4) from angle brackets (5, 7, and 8) and remove pulley
guard (6) from main frame assembly.
d. Loosen hose clamp (11, FIGURE 2-14, Sheet 3) and remove nonmetallic hose (12) and hose clamp (11) from hose
elbow (17).
e. Remove reducer bushing (13) with nipple and hose tee (18) from pump inlet port.
f.
Remove high pressure hose assembly (1) female adapter end from hose elbow (19).
g. Remove reducer bushing (14) with hose elbow (19) attached from pump outlet port.
h. Loosen four hexagon nuts (8) on adjustable base (2) that axial pistons pump (16) rests on
i.
Turn tension adjustment (10) counterclockwise until slots contact threaded studs.