TM 55-1905-223-24-7
2-18.
Replace/Repair Motor and Pump Assembly. (FIGURE 2-12)
This task covers: a. Removal,
b. Repair,
c. Replacement.
INITIAL SETUP:
Tools
Equipment Condition
Tool kit, general mechanic's,
RO desalinator shut down. Refer
to TM 55-1905-223-10.
RO desalinator tagged "Out of
Materials/Parts
Service, Do Not Operate."
High pressure hose assembly,
P/N 7392
Nonmetallic hose, P/N PVTBF075
REMOVAL
a. Close appropriate inlet feedwater gate valve (2, FIGURE 2-12, Sheet 1) for RO desalinator unit under
maintenance.
b. On left side of watermaker, remove ten machine screws (2, FIGURE 2-12, Sheet 2) and remove louvered panel
(1) from main frame assembly (3).
c. On main frame assembly (3), remove eleven machine screws (4) from angle brackets (5, 7 and 8) and remove
pulley guard (6) from main frame assembly.
d. On motor and pump assembly (6, FIGURE 2-12, Sheet 3), disconnect outlet high pressure hose assembly (23)
male hose adapter (4) from RO module No. 1.
e. Disconnect and remove inlet nonmetallic hose (13) and hose clamp from micron filter No. 1.
f. Remove access cover (24) on alternating current (ac) motor (1) by removing four screws (25) to gain access to
wiring terminal box (26).
g. On inside of wiring terminal box (26), tag and disconnect red, black, and white power cable leads.
h. Disassemble outlet conduit elbow (11) and outlet conduit (12), and pull power cable from ac motor (1) terminal
box (26).
i. Replace ac motor (1) access cover (24) on terminal box (26) and secure with four screws. This action will protect
ac motor wiring.
2-48
|