TM 55-1905-223-24-4
e. Clean all parts in solvent; use compressed air to dry.
f.
Replace the gerator planetary.
CAUTION
Ensure the gerator planetary is replaced in the original position.
g. Measure the tip clearance (FIGURE 3-64). Maximum: 0.007 inch (0.1678 mm).
FIGURE 3-64. Tip Clearance Measurement.
h.
Measure the clearance of the gerator drive/gerator planetary to port plate (FIGURE 3-65). Maximum: 0.005 inch
(0.127 mm).
FIGURE 3-65. Drive/Planetary to Port Plate Measurement.
3-72
|