TM 55-1905-223-24-4
(3) Replace burden resistor (20).
(4) Replace toggle switch (22).
d. Replace relays (8, 9, 12, 13, & 14) in control box assembly (15).
e. Install panhead screws (10).
f.
Install resistor (18) on mounting bracket (19).
g. Secure with bolts (16) and nuts (17).
h. Install resistor assembly (7) in instrument panel assembly.
i.
Secure with machine screws (5) and lockwashers (6).
j.
Connect all wiring harnesses as tagged to terminal board (4).
k.
Replace door assemblies (para. 2-14 and 2-15).
l.
Replace instrument panel (para. 2-12).
m. Remove "Out of Service" tags and restore equipment to operation (TM 55-1905-223-10).
3-13
|