(2)
Remove burden resistor (20).
(3)
Remove transformer (21).
(4)
Remove cross-current bracket (23).
e. Remove voltage regulator (1).
(1)
Remove four machine screws (2) and lockwashers (3).
(2)
Carefully move out voltage regulator for access to back.
(3)
Tag and disconnect wiring.
(4)
Remove regulator.
f.
Remove rubber grommet (11).
g. Tag and disconnect electrical leads to resistor assembly-(7).
h. Remove machine screws (5) and lockwashers (6).
i.
Remove resistor assembly (7).
j.
Remove bolts (16) and nuts (17).
k.
Remove resistor (18) from mounting bracket (19).
REPAIR
Repair is accomplished by replacement of rubber grommet (11), relays (8, 9, 12, 13, 14), toggle switch (22) burden
resistor (20), transformer (21) resistor assembly (7), resistor (18), voltage regulator (1) and wiring harnesses.
ASSEMBLY
a. Replace rubber grommet (11).
b. Replace voltage regulator (1).
(1)
Position voltage regulator in place.
(2)
Connect wiring as tagged.
(3)
Install machine screws (2) and lockwashers (3).
c.
Replace paralleling module.
(1)
Install cross-current bracket (23).
(2)
Replace transformer (21).