Table 2-1. Preventive Maintenance Checks and Services (PMCS)-CONT
E - Every 20 hours
W - Weekly
Q - Quarterly
S - Semiannually
A - Annually
B - Biennially
INTERVAL
ITEM
ITEMS TO BE
Procedures
NO.
INSPECTED/SERVICED
EWQ
S
A
B
12.
Fuel system - CONT
CAUTION
CONT
When using the starting motor to vent the system, do not engage it
for more than 30 seconds at a time. Wait 2 minutes between
engagements.
WARNING
It is necessary to put the engine in the RUN position. Because the
engine may start, be sure to follow all, safety, precautions. Use the
normal engine starting procedures.
Venting the high pressure lines.
a. Loosen the fittings at the injector.
WARNING
High pressure fuel could cause penetration of the skin.
b. Crank the engine to allow entrapped air to bleed from the line. Tighten the
fittings.
2-11
|