Table 2-1. Preventive Maintenance Checks and Services (PMCS)-CONT
E - Every 20 hours
W - Weekly
Q - Quarterly
S - Semiannually
A - Annually
B - Biennially
INTERVAL
ITEM
ITEMS TO BE
Procedures
NO.
INSPECTED/SERVICED
EWQ
S
A
B
12.
Fuel system-CONT
NOTE
CONT
Air/fuel can be pumped from LP lines, fuel filter, and fuel pump
using the hand lever on the lift pump is the fuel solenoid valve is
energized to venting the low pressure (LP) lines and the fuel filter
a. In order to bleed the fuel system, the shutoff must first connect
jumperwires from the positive and negative battery cable on the starter to
the fuel shutoff valve solenoid terminal
b. Open the bleed crew, then operate the hand lever on the lift pump until the
firs flowing from the fitting is free of air. Tighten the bleed screw.
Venting at the fuel pump.
a. Open the pump bleed screw.
b. Follow the pump bleed procedures listed above.
c. Air can also be vented through the fuel drain manifold line by operating the
starting motor.
2-10