TM 55-1905-223-24-17
3-10d. DISCHARGING THE REFRIGERANT SYSTEM.
This task covers:
a. Discharging
INITIAL SETUP :
Tools:
Equipment Condition
Refrigeration Unit Service Tool Kit
Install Service Manifold
Goggles
General Safety Instructions
WARNING
Gloves
Refrigerant Recovery and Recycle Unit
DANGEROUS CHEMICAL REFRIGERANT
UNDER PRESSURE is used in the operation
of this equipment.
DISCHARGING
WARNING
DANGEROUS
CHEMICAL
REFRIGERANT
UNDER
PRESSURE is used in the operation of this equipment.
NOTE
Use great care to avoid contact with liquid refrigerant or inhaling
refrigerant gas being discharged from any container under
pressure. Sudden and irreversible tissue damage can result
from freezing.
Wear thermal protective gloves and a face
protector or safety glasses in any situation where skin or eye
contact is possible.
Prevent contact of refrigerant gas with flame or hot surfaces.
Heat causes the refrigerant to break down and form carbonyl
chloride (phosgene), a highly toxic and corrosive gas.
Change3 3-15
|