TM 55-1905-223-24-17
2-24. Repair Fan, Ventilating (Supply Fan #3). (FIGURE 2-14)
This task covers:
a. Repair
INITIAL SETUP :
Tools
Equipment Condition
Tool kit, general mechanic's,
Alternating current motor removed
Tool kit, electrician's,
Puller, 5120-00-516-3i20
Hydraulic Press, PN 2009-13
Materials/Parts
Bearings PN 416821-2D
REPAIR
Repair consists of replacing the motor bearings.
a.
Disassemble motor (1) as follows:
(1)
Remove woodruff key (15) from shaft spline.
(2)
Remove bolt (17) and remove back end bracket (11) and dirt deflector (14).
(3)
Remove fan cover bolt (7) and remove fan cover (2). Remove grease entry tube (4) from bracket (5).
(4)
Remove fan clamp (24) and remove outer fan (3) from motor shaft (16).
(5)
Remove front end bracket bolt (6) and remove front end bracket (5). Remove washer (23).
(6)
Remove the shaft (16) and bearings (12, 22) assembly from the motor.
(7)
Make the following measurements and records:
(a)
Measure the distance from back bearing (12) to the impeller end of the shaft (16).
(b)
Measure the distance from front bearing (22) to the outer fan (3) end of the shaft (16).
2-64
|