Click here to make tpub.com your Home Page

Page Title: Repair Heater, Duct Type, Stationary (Ducts #8, #13, and #15)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 55-1905-223-24-17
2-21. Repair Heater, Duct Type, Stationary (Ducts #8, #13, and #15). (FIGURE 2-11)
This task covers:
a. Repair
INITIAL SETUP :
Tools
Equipment Condition
Tool kit, general mechanic's,
Circuit breaker switch OFF, power panel
locked and tagged "Out of Service -
Tool kit, electrician's,
Do Not Operate."
See TM 55-1905-223-10 for HVAC systems
Materials/Parts
operation and equipment location.
Heating element
P/N 52424177 (Duct 8)
P/N 52424178 (Ducts 8, 13, and 15)
P/N 52424179 (Ducts 13 and 15)
Electrical tag, Item 1, Appendix C
REPAIR
Repair consists of replacing heating elements.
a.
Open heater front cover (7).
b.
Tag electrical line connections at terminal ends of heating element (4).
c.
Remove terminal nuts (6) and washers (5).
d.
Separate line connections from terminal ends of heating element (4).
e.
Remove mounting flange screws (2) securing heating assembly (3) to terminal box (1).
f.
Slide heating assembly (3) out of terminal box enclosure (1).
g.
Remove heating elements (4).
h.
Install heating elements (4) into heating assembly (3).
i.
Slide heating assembly (3) into terminal box enclosure (1).
2-57

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business