TM 55-1905-223-24-17
j.
Secure heating assembly (3) to terminal box (1) with mounting flange screws (2) at top and bottom.
k.
Install electrical line connections on terminal ends of heating element (4) as tagged.
CAUTION
When making line connections to heating element terminals
FOR FINNED TUBULAR HEATERS ONLY, apply a 1/4-inch
wrench to flat section of terminal immediately below threads.
Otherwise, damage to terminal may result from element
twisting.
l.
Secure line connections to heating element (4) with terminal washers (5) and nuts (6).
m.
Close heater front cover (7).
n.
Operational check:
(1)
Unlock power panel and switch circuit breaker ON.
(2)
Refer to TM 55-1905-223-10 for details on control settings.
(3)
Remove "Out of Service - Do Not Operate" tag from circuit breaker.
2-56
|