4-27. PLATFORM - REPLACE (Continued)
4-27
Figure 4-31. Platform Cables (Sheet 2 of 2).
NOTE
Loosen strain relief covers (1, Figure 4-32) and pull tagged cables far
enough to install tags on individual wires for ease of
installation.
(5) Disconnect cable wires for the safety bumpers (1 and 2) at the junction box (6) for ease of installation.
(6) Repeat step (5) for the removable platform section (3), platform limit switches, platform lights (4) and platform
control box (5).
Figure 4-32. Junction Box.
(7) Cut terminals from all disconnected wires.
(8) Carefully pull from junction box (2, Figure 4-32) and tag each cable for ease of installation.