TM 55-1730-228-13&P
3-22. LIMIT SWITCHES/ TOGGLE SWITCHES-REPLACE (Continued)
3-22
Figure 3-20. Limit Switch Replacement (Sheet 2 of 2).
a. LIMIT SWITCH:
(1) Removal:
(a) Remove two screws (1, Figure 3-20) from limit switch cover (2). Remove limit switch cover (2) and
gasket (3).
(b) Tag and disconnect wires (4) from limit switch.
(c) Remove strain relief nut (5) from limit switch housing (6). Pull wires out of housing (6).
(d) Remove two screws (7) from limit switch housing (6). Remove housing (4) from mounting bracket
(8).
(2) Installation:
(a) Position limit switch housing (6). Install two screws (7) to secure housing to mounting bracket (8).
(b) Thread wires into limit switch housing (6). Install strain relief nut (5).
(c) Connect wires (4) to limit switch using the tags for identification.
(d) Position limit switch cover (2) with gasket (3) and install two screws (1).
(e) Adjust limit switch. Refer to para 3-21.
(f) Connect battery ground cable. Refer to para 3-17.
(g) Perform operational check for proper function.
GO ON TO NEXT PAGE
3-54
|