TM55-1730-228-13&P
3-17. BATTERY CABLES REPLACE (Continued)
3-17
b. INSTALLATION:
(1) Secure positive (+) cable (14) on starter solenoid with lockwasher (19) and nut (18).
(2) Secure negative (-) cable (12) on frame with capscrew (15) lockwasher (17) and nut (16).
(3) Route positive cable (14) to battery box (5). Guide cable through hole in battery box. Slide exposed end
of cable into clamp of positive terminal (10) and tighten both clamp bolts (13).
(4) Route negative cable (12) to battery box (5). Guide cable through hole in battery bo . Slide exposed end
x
of cable into clamp of negative terminal (7) and tighten both clamp bolts (11).
(5) Install positive terminal (10) on positive post of battery (8). Tighten terminal nut (9) to secure terminal (10).
(6) Install negative terminal (7) on negative post of battery (8). Tighten terminal nut (6) to secure terminal (7).
(7) Reinstall cover (4) on battery box (5) and install strap (3) on rods (20). Secure with two washers (2) and
two nuts (1).
(8) Install tiestraps as needed to keep cables (12 and 14) from rub points.
(9) Perform operational check for proper function.
END OF TASK