TM 55-1730-226-13
WARNING
N o smoking within 50 feet of the
O x y g e n Servicing Unit. In addition,
p a r t s which come into contact with
o x y g e n must be " C L E A N E D  F O R
OXYGEN  SERVICE."  Personnel
u s i n g the Oxygen Servicing Unit m u s t
be familiar with safety regulations
r e g a r d i n g the handling of oxygen.
Oxygen may cause violent explosions
when ignited by fire or sparks or
w h e n in contact with any type of com-
bustible material, particularly hydro-
c a r b o n s .  S u c h explosions could cause
death or injury to personnel and/or
damage to equipment.
WARNING
Do n o t disconnect any plumbing
w i t h o u t first bleeding all pressure
from the line(s) per paragraph
4.4. Pressurized oxygen emanating
f r o m the open end could injure per-
sonnel if so directed.
Replacement of oxygen pigtail (46,
47  or 4 8 )
1.
2.
Replacement of manifold (32) per paragraph
4.6.
Replacement of BOTTLE PRESSURE OUTLET
3.
V A L V E (31) per paragraph 4.7.
Replacement of REGULATOR PRESSURE
4.
O U T L E T VALVE  (26) per paragraph 4.8.
5.
Replacement of output service line (11) per
6.
Replacement of roller assembly (49) per
P e r f o r m i n g a leak check per paragraph 4.11.
7.
4-2

Privacy Statement - Press Release - Copyright Information. - Contact Us