Page Title: CLEANING
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

ROCKER ARM COVER ASSEMBLY REPAIR (CONTINUED)
CLEANING
WARNING
Dry-cleaning solvent used to clean parts is poten-
tially dangerous to personnel and property. Do
not use near open flame or excessive heat. Flash
point of solvent is
A
Clean gasket mating surfaces with dry-cleaning solvent
(item 8, Appx
or mineral spirits paint thinner (item 21,
Make sure mating surface is free of excess gasket material.
B
c
Wipe dry with lint-free cloth (item 6, Appx C).
Clean four drain holes with fine cleaning wire.
D
E
Flush oil line with clean diesel fuel.
WARNING
Particles blown by compressed air can be
dangerous. Direct air stream away from person-
nel in immediate area.
F
Dry oil inlet with clean, filtered,
compressed air.
INSPECTION AND REPAIR
C Inspect bolt holes for damaged or excessively worn threads.
A Inspect cover for cracks, nicks or dents in gasket mating
D Replace rocker arm cover assembly if damaged.
surface.
E
Inspect oil line for cracks, punctures, nicks and dents that
B Inspect area around lifting bracket bolt hole for cracks.
may leak or limit oil flow. Replace if defective.
0859