d. Air Lubricator (8, figure 2-1). Through the sight
150:1). Close the oil control valve (13) and allow the
pump to build up a stable pressure.
dome on the air lubricator, time the injection of oil into
the air stream. (Refer to figure 4-4. ) It should be three
3. Monitor the output pressure on the manifold
drops per minute. The oil flow may be adjusted by
oil pressure gages (15 & 16) and compare to that
rotating the adjusting screw; counterclockwise for more
calculated in step b.
oil flow, clockwise for less.
e. Air Pressure Regulator (3). Remove the bottom
NOTE
plug and check for contamination. If contamination is
visible, clean plug, body, and valve seat using solvent
A record of any deviation should be
conforming to PD-680, Type II.
maintained so that any necessary
adjustments to obtain the correct pressures
f.  Air Filter (2). Remove rigid filter element, tap
during the hose test may be made.
on hard surface, and blow off with air blow gun.
NOTE
g. Air-Operated Pump (10). With a hose (21)
connecting the output oil manifold (18) with the oil return
As the moving parts within the pump
port and adaptor fitting (14) conduct a series of tests at
become worn, the ratio between the air input
various air input pressures.
pressure and the oil output pressure will
drop slightly. The operating air pressures
1. Set the air pressure regulator (3) and open
should be revised accordingly.
the air control valve (9).
4. Following this series of tests the Hose
2. Compute the ratio of the air input pressure
Tester may be shut down using the normal operating
to the oil output pressure. (It should be approximately
procedure.