Table 2-1. Preventive Maintenance Checks and Services (PMCS)-CONT
E - Every 20 hours
W - Weekly
Q - Quarterly
S - Semiannually
A - Annually
B - Biennially
ITEM
INTERVAL
ITEMS TO BE
Procedures
NO.
INSPECTED/SERVICED
EWQ
S
A
B
5.
Battery - CONT
c. Install and tighten the battery cables (TM 55-1905-223-24-18).
CONT
6.
Oil filter
Check condition of used oil. Thin, black oil
indicates fuel dilution. Milky discoloration
indicates coolant dilution.
CAUTION
Diluted oil can cause severe damage
to the engine.
a. Send oil sample to the Army Oil Analysis Program (AOAP) lab.
NOTE
If oil is contaminated a sample must be sent to the AOAP lab for
spectrometric analysis.
b. If necessary, change lubricating oil. Refer to LO 55-1905-223-12.
NOTE
Allow time for the oil to settle in the pan after engine shutdown.
c. Drain the oil as follows:
(1) Open the suction valve for the sump pump.
Change 1
2-6.1/(2-6.2 blank )