TM 9-6920-737-10
CREW STATION UTILITY PANEL (Continued)
Key
Control o Indicator
r
Function
3
ON indicator
Lights orange to indicate circuit breaker (2)
is on and ac power is applied to 120 V ac
utility outlets and COMMUNICATION
HEADSETS panel.
4
COMMUNICATION HEAD-
On/off control and overload protection for
SETS ON/OFF circuit breaker
120 V ac power applied to Communication
Headsets 24V dc power supply.
5
BROW PAD POWER
On/off control and overload protection for
ON/OFF circuit breaker
24 V dc to Crew Station BROWPAD (Recoil)
DRIVER from 24V dc supply.
OVERTEMPERATURE
6
CREW COMPARTMENT
Lights red when an overtemperature condition
PWR SUPPLY ASSEMBLY
exists in the Crew Station Power Supply
assembly
7
ISU/CR/ASU DEFLECTION
Lights red when an overtemperature condition
AMPLIFIER indicator
exists in the 3-CRT Color Monitor Deflection
Amplifier in the Crew Station.