TM 9-6920-737-10
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS
The U-COFT is installed on a concrete pad and consists of three, interconnected shelters:
Computer Shelter
Trainer Shelter
Integration Shelter
The Computer and Trainer Shelters are placed parallel to each other, approximately four feet apart. The
Integration Shelter is placed across the end doors of the Computer and Trainer Shelters to provide a U-shaped
interconnected complex. Butting kits between the end doors of the parallel shelters and the side doors of
Integration Shelter provide the connections for a weather tight integrated complex. Entrance to the complex is
provided at the right-hand end of the Integration Shelter. Emergency exits are provided at the Integration
Shelter, opposite the entrance, and at the far ends of the Computer and Trainer Shelters.
The Interior of the U-COFT complex is environmentally controlled by air conditioning units installed in each
shelter. The air conditioning units provide the heating cooling, and humidity control necessary for equipment
operation and human comfort.
The Trainer Shelter contains the Crew Station (1), Air Conditioner (2), Instructor Operator Station (IOS) (3), and
Terminal Printer (4).
The Integration Shelter provides a student briefing area (5) containing the Remote Monitor Station (6) and a
maintenance area (7). These areas are divided by a folding curtain. An air conditioner (8) is located between
the two areas.
The Computer Shelter contains the Disk Drive Unit (9), General Purpose Computer (GPC) (10), three Air
Conditioners (11) (two on one wall and one on the opposite wall), and the Special Purpose Computer (SPC)
(12).
The following paragraphs provide the location and descriptive details of the major units contained within each
shelter.
1-7
|