2-10.  Installation  Instructions  for  the  M114A1
Howitzer. To mount the barrel in the M114A1 howitzer
and boresight the device, follow steps 1 through 13.
Step 1: To remove the obturator group, obturator spring,
and firing mechanism housing assembly,  refer to the
Step 5: Insert the adapter (top up) in the breech-block.
operator's manual for the major caliber weapon.
Step 2: Remove adapter nut and washer.
Step 6: Place the washer on the adapter. Tighten the
nut all the way down, then loosen it two turns.  The
loosening of the nut allows the breech to be closed fully.
Step 3: Place the obturator spring in the firing
mechanism housing recess.
Step 7: Remove the four head cap socket screws and
the adapter cap.
Step 4: Install the key in the keyway and secure with a
screw.
NOTE
Adapter PN 11578876 does not have
Step 8: Remove the elevating arc from the gun barrel by
keyway.  Use as issued with screw
removing the two mounting screw.
and jam nut.
Change 1 2-21