ARMY
TM 9-6650-235-13&P
MARINE CORPS
TM-08552A-13&P
5-40.
BORESCOPE OPTICAL CASE--MIAINTENANCE INSTRUCTTONS.
This task covers:
a. Disassembly
c. Reassembly
b. Cleaning/Repair
INITIAL SETUP
Tools and Special Tools
Instrument and fire control shop
equipment SC 4931-95-CL-A07
Hot melt glue gun HYSOL 101
Materials/Parts
Silicone adhesive sealant
(item 14, app D)
Solvent, trichloroethane
(item 16, app D)
Paper towel, disposable wiper
(item 11, app D)
Glue, hot melt (item 6, app D)
DISASSEMBLY.
1
NOTE
Early configuration fiberglass cases are not
repairable. This procedure covers repair of late
configuration polyethylene cases only.
a. Remove molded insert (1) and panel cover (2)
from molded case (3).
b. Remove five caplugs (4) from molded case (3).
c. Remove humidity indicator (5) from molded case
(3).
d. Remove pressure relief valve (6) from molded
case (3).
5-135
|